          光纖光譜儀,氧含量傳感

          光纖光譜儀,積分球,均勻光源,太赫茲系統(tǒng)應(yīng)用專家
          光譜儀
          >>
          光譜儀系統(tǒng)
          >>
          激光器
          >>
          激光測(cè)量
          >>
          寬帶光源
          >>
          LED和影像測(cè)量
          >>
          光譜儀附件
          >>
          太赫茲系統(tǒng)
          >>
          濾光片
           濾光片
          石墨烯納米材料
           石墨烯納米材料
           


          NEOFOX氧含量傳感系統(tǒng)

           

          NEOFOX氧含量傳感系統(tǒng)

          NEOFOX氧含量傳感系統(tǒng)

          新的NeoFox相位氧含量測(cè)量系統(tǒng)是基于熒光的光學(xué)傳感系統(tǒng),具有較高的測(cè)量穩(wěn)定性,方便地校準(zhǔn)步驟,降低您的測(cè)量成本等特性,廣泛的使用于氧含量傳感的領(lǐng)域中。

          NeoFox采用測(cè)量熒光的淬滅周期,相位和強(qiáng)度的方法來獲得氧含量的數(shù)值,特別適合于靈敏度較高或漂移較大的實(shí)驗(yàn)環(huán)境,具有較高的系統(tǒng)穩(wěn)定性。

          NeoFox只有同類相位測(cè)量系統(tǒng)一半的價(jià)格。

           

          Probe Specifications:
          FOXY Formulation FOSPOR Formulation HIOXY Formulation
            (general-purpose coating) (high-sensitivity for low levels of O2) (for hydrocarbon environments)
          O2% range (at 1 ATM): 0-100% 0-10% 0-20.9%
          DO range (ppm at 1 ATM): 0-40 ppm 0-4 ppm 0-8 ppm
          Temperature range: -50-+80 oC for probes -50-+80 oC for probes -50-+60 oC
          0-60 oC for patches 0-60 oC for patches NA
          O2% resolution: 0.01-0.05% .001% 0.01-0.05%
          DO resolution (at room temp): 4-20 ppb 0.4-2 ppb 4-20 ppb
          O2% accuracy: 5% of reading 5% of reading 5% of reading
          DO accuracy: 5% of reading 5% of reading 5% of reading
          Min. detectable level in gas: 0.01% - 0.05% 0.001% - 0.01% 0.01% - 0.05%
          Response time: < 1 second in gas < 1 second in gas < 1 second in gas
          ~30 seconds with overcoating in gas ~30 seconds with overcoating in gas ~45 seconds in pure water
          ~45 seconds in pure water ~45 seconds in pure water
           
          Patch Specifications:
            FOXY Formulation FOSPOR Formulation HIOXY Formulation
          02% range (at 1 ATM): 0-100% 0-20.9% 0-100%
          DO range (ppm at 1 ATM): 0-40 ppm 0-8 ppm 0-40 ppm
          Temperature range: -20 to +60 oC for patches -20 to +60 oC for patches -20 to +60 oC for patches
          02% resolution (20 sex averaging): 0.05% 0.01% 0.05%
          DO resolution (at room temp): 20 ppb 4 ppb 20 ppb
          02% accuracy: 5% of reading 5% of reading 5% of reading
          DO accuracy: 5% of reading 5% of reading 5% of reading
          Min. detectable level: 0.1% O2 0.01% O2 0.1% O2
          Min detectable level in water (at room temp): 40 ppb 4 ppb 40 ppb
          Response time: <1 second in gas <1 second in gas <1 second in gas
            ~30 seconds with overcoating in gas ~30 seconds with overcoating in gas  
            ~45 seconds in pure water ~45 seconds in pure water ~45 seconds in pure water
           
          Sterilization Guide:
            FOXY Formulation FOSPOR Formulation HIOXY Formulation
          Form factor: Probes/Patches Probes/Patches Probes
          Autoclavable: No No Yes
          Calibration:     Single point reset required after sterilization

           


          玻色智能科技有限公司光譜儀專家
          上海玻色智能科技有限公司
          上海: (021)3353-0926, 3353-0928   北京: (010)8217-0506
          廣州: 139-0221-4841   武漢: 139-1733-4172
          全國(guó)銷售服務(wù)熱線:4006-171751   Email: [email protected]